ST200 Online Intelligent Soft Starter Without Bypass

ST200 motor soft starter is a new type motor starting and protection device that is integrated with power electronic technology, microprocessor and automatic control

No need to built by pass contactor with SCR controlling new technology applying—-innovation and cost saving

ST200 Online Soft Starter Overview

ST200 motor soft starter is a new type motor starting and protection device that is integrated with power electronic technology, microprocessor and automatic control. This soft starter is able to steadily start and stop motor without step change so as to avoid mechanical or electric impact resulted from using conventional starting modes such as direct starting, star-delta starting and auto voltage reducing starting, and effectively reduce starting current and distribution capacity.
No need to built by pass contactor with SCR controlling new technology applying—-innovation and cost saving.

ST200 Online Soft Starter 3phase 380V For Motor Not By Pass Contactor

Multiple Motor Protection Functions

  • Phase missing protection 
  • Over heat protection 
  • Over current and over load protection 
  • Output unbalance protection 
  • Under voltage and over voltage protection 
  • Load circuit protection 
  • Under load protection

Technical Specifications

ST200Description
Input Power SupplyInput VoltageThree-phase 380V/690 AC
 Frequency50/60Hz
Adaptive MotorSquirrel-cage three-phase asynchronous motor
Starting TimesIt is recommended not to exceed 20 times per hour.
Control ModeOperation panel control. 
Operation panel + external control.
External control. 
External control + COM control. 
Operation panel + external + COM control.                      
Operation panel + COM control.                   
COM control. 
No start or stop operation.
Start ModeCurrent-limiting to start.         
Voltage ramp to start.                   
Torque control + current-limiting to start.                
Torque control + voltage ramp to start.                   
Current ramp to start.
Voltage current-limiting double closed-loop start.
Stop ModeSoft stop.
Free stop.
Protective FunctionOpen loop protection for external instantaneous stop terminals.
Over-heat protection for soft starter.
Protection for too long starting time.
Input open phase protection.
Output open phase protection.
Unbalanced three-phase protection.
starting over current protection.
Running overload protection.
Under voltage protection for power voltage.
Overvoltage protection for power voltage.
Protection for fault parameter setting.
Load short circuit protection.
Auto restart or incorrect wiring protection.
Incorrect wiring protection of external control stop terminals.
AmbientPlace to be usedIndoor location with good ventilation free from corrosive gas and conductive dust.
AltitudeBelow 1000M. It have to rise the rate power when the altitude is more than 1000M.
TST200perature-30 +55 oC
Humidity90%RH without dew condensation.
Vibration<0.5G
StructureProtection ClassIP20
Cooling PatternNatural wind cooling.

Standard Wiring Diagram